OL 740-73 Transmittance Attachment
The OL 740-73 is an exit optics module which mounts to the exit port of the OL Series 750 Monochromator and is used for measuring the spectral transmittance of optical materials. The module uses two fused silica lenses. The first lens forms a collimated, monochromatic beam and the second lens focuses the beam on the detector. The sample compartment is located between the two lenses in the collimated portion of the beam.

OL 750-10SF Short Focus Imaging Optics Module
The OL 750-10SF Short Focus Imaging Optic Module consists of a pair of front aluminized mirrors mounted in a rugged fixture which is attached to the exit port of the OL Series 750 Monochromator. The OL 750-10SF/OL Series 750-M Monochromator combination produces a high quality image of the exit aperture with a 1:1 magnification. The unity magnification enables it to be used as an excellent means of underfilling detectors when performing Detector Spectral Response measurements on detectors as small as 500 µm in diameter.
Refer to Bulletin 140 for further info on:
- General 750-10 Applications

OL 750-10T/R Mirror Collimating Optics Module
The OL 750-10T/R Mirror Collimating Optics Module serves as a convenient, easy to use attachment for the OL Series 750 System when measuring spectral transmittance or specular reflectance at a fixed angle. It consists of a pair of front surface aluminized mirrors mounted in a rugged fixture which is attached to the exit port of the OL Series 750 Monochromator. The high degree of uniformity of the collimated, monochromatic beam enables the user to make accurate measurements of spectral transmittance and specular reflectance.
Refer to Bulletin 140 for further info on:
- General 750-10 Applications

OL 750-10C Mirror Collimating Optics Module
The OL 750-10C Mirror Collimating Optics Module consists of a pair of front aluminized mirrors mounted in a rugged fixture which is attached to the exit port of the OL Series 750 Monochromator.The high degree of collimation and superb uniformity produced by the OL 750-10C/OL Series Monochromator combination enables it to be used as an excellent source of collimated monochromatic flux, with a beam diameter of up to 2 inches, as well as a superior source for performing Detector Spectral Response measurements on relatively large area detectors.
Refer to Bulletin 140 for further info on:
- General 750-10 Applications

OL 740-70 Integrating Sphere Reflectance Attachment
The OL 740-70 is used with OL Series 750 Automated Spectroradiometric Measurement System for measuring the diffuse or total hemispherical reflectance of materials. Accurate reflectance measurements can be made with the specular component included or excluded. Specular (mirror) samples can also be measured at 10° incident angle. Spectral transmittance of clear and diffusely transmitting materials can also be measured. The attachment uses a true double beam optical design with a manual beam switch which minimizes errors found in less accurate single beam designs. The OL 740-70 can be used over the 250 to 2500 nm wavelength range.
Refer to Bulletin 66 for further info on:
- Performance Specifications
- Design Information

OL 740-70G Gold Integrating Sphere Reflectance Attachment
The OL 740-70G is a gold coated version of the OL 740-70 described above. It is used over the wavelength range of 2 to 18 µm.

OL 750-75MA Specular Reflectance Attachment
The OL 750-75MA is used with the OL Series 750 Automated Spectroradiometric Measurement System in conjunction with OL Series 740-20
Source Attachment for measuring the spectral specular reflectance of materials as a function of both wavelength and angle of incidence.
The all-mirror optical design enables the attachment to be used over the entire 0.2 to 30 µm wavelength range. Accurate measurements
can be made without the use of a standard (calibrated mirror) by directly measuring the incident beam. The flexible receiver design
allows the angle of incidence to be selected from 10° to 60° with an accuracy of ±0.1° .
Refer to Bulletin 76 for further info on:
- Performance Specifications
- Features
- Design Information

OL 740-4P Off-Axis Parabolic Telescope
The OL 740-4P Off-Axis Parabolic Telescope is designed to facilitate a broad range of radiometric measurements over the entire UV to IR wavelength range. The telescope can be interfaced to the entrance port of the OL Series 750 Monochromator system to measure spectral irradiance or radiance of collimated, point or diffusely radiating sources, or it can be interfaced to the exit port to obtain a highly collimated, monochromatic flux level and used to calibrate various detectors or radiometer systems. The telescope may also be interfaced to the OL 480 Blackbody Source to obtain a collimated, broadband source at various blackbody temperatures, or to the OL 300 Low Light Calibration Source (with starlight shaping filter) to obtain a collimated star standard.
Refer to Bulletin 72 for further info on:
- Performance Specifications
- Technical Specifications
- Design Applications
- Monochromator Minimum Source Sizes